Service offerings are now integral components of the industry’s value proposition, characterized by comprehensive technical support, digitalization, and lifecycle management.
Type: Copper
Rated Voltage: 1500v
Standard: IEC 62930
Jacket: Soft annealed flexible tinned copper conductor — Class 5 as per IEC 60228
Packing: Plastic spools-coils or shrink wrap or non returnable wood drums as per customer requirement
PV1-F is a single-core, tinned copper photovoltaic cable engineered for the DC interconnection of PV modules, combiner boxes and inverters. The cross-linked polyolefin (XLPO) insulation and sheath system delivers UV resistance, flame retardancy, and a designed service life of 25 years under standard installation conditions.
The same cable platform is also produced as H1Z2Z2-K on a built-to-spec basis, and ANPU manufactures equivalent variants against any project’s specified standard — see the customization section below for how it works.
Verified parameters for procurement and engineering review. Customized values available on request.
Cable Designation
PV1-F / H1Z2Z2-K (62930 IEC 131/132)
Rated Voltage
1500V DC
Conductor
Tinned Copper, Class 5
Conductor Standard
IEC 60228
Insulation
XLPO (120°C WDZJ)
Outer Sheath
XLPO (120°C WDZH)
Operating Temp
−40°C to +90°C
Max Conductor Temp
120°C (≤20,000 hrs cumulative)
Short-Circuit Temp
250°C (≤5 s)
Voltage Test
6.5 kV / 5 min @ 20°C water
Flame Retardant
IEC 60332-1-2
Min Bending Radius
4 × Outer Diameter
Designed Service Life
25 Years (standard installation)
Available Cross-Sections
1.5 – 150 mm²
Sheath Colours
Black / Red / Blue (custom available)
Halogen-Free / LSZH
Yes
In free air at 30°C ambient. Use the values below for system design and cable sizing.
| Cross Section (mm²) | Current (A) | Outer Dia. (mm) | Weight (kg/km) | Type |
|---|---|---|---|---|
| 1×1.5 | 31 | 4.8 | 37 | IEC 131 |
| 1×2.5 | 42 | 5.2 | 48 | IEC 131 |
| 1×4 | 57 | 5.8 | 64 | IEC 131 |
| 1×6 | 72 | 6.3 | 85 | IEC 131 |
| 1×10 | 98 | 7.6 | 131 | IEC 131 |
| 1×16 | 132 | 8.9 | 191 | IEC 131 |
| 1×25 | 183 | 11.4 | 304 | IEC 131 |
| 1×35 | 227 | 12.8 | 404 | IEC 131 |
| 1×50 | 287 | 13.0 | 526 | IEC 132 |
| 1×70 | 361 | 15.0 | 705 | IEC 132 |
| 1×95 | 433 | 16.8 | 988 | IEC 132 |
| 1×120 | 508 | 18.7 | 1231 | IEC 132 |
| 1×150 | — | 20.8 | 1521 | IEC 132 |
IEC 131 — free movable / hanging / fixed laying. IEC 132 — fixed installation only, not for direct burial.
ANPU manufactures PV1-F to IEC 62930 as the standard product line. Beyond standard production, the same cable platform is also tailored to your project’s required standard — H1Z2Z2-K or any equivalent regional designation — adjusting conductor class, insulation thickness, sheath marking, and test sequence to match.
You provide the standard reference, cross-section, marking and quantity. ANPU’s engineering team confirms the spec, runs samples in the in-house lab, and produces to your project requirements.
IEC 62930 — IEC 131 / IEC 132
ANPU’s standard product line. Common cross-sections (4 / 6 / 10 mm²) are typically held in stock for fast dispatch to projects worldwide.
TÜV 2 PfG 1169 — European designation
For EPCs and distributors who specify the H1Z2Z2-K designation. ANPU produces it as a customized order matching your project’s technical profile — conductor, insulation and sheath all built to your reference standard.
Regional & project-specific standards
For projects requiring a specific regional standard or local equivalent, ANPU manufactures to your project’s specified standard or to an equivalent international construction confirmed during RFQ.
You submit your required standard, size, length, sheath colour and marking. ANPU’s sales team replies within 24 hours.
ANPU’s R&D engineers confirm the build spec, identify any standard-specific deltas, and issue a technical proposal for your sign-off.
Trial production with full electrical and mechanical testing in the 3,000 m² in-house laboratory. Samples shipped on request.
Mass production with batch QC. Packaging in plastic spools, shrink-wrap coils or non-returnable wooden drums per your shipping preference.
From rooftop arrays to utility-scale solar farms, this cable platform handles the DC interconnection in global PV projects.
String-to-combiner and combiner-to-inverter DC connections for ground-mount installations at MW / GW scale.
Panel interconnection and inverter wiring for residential and commercial rooftop installations.
Humidity-resistant performance for floating photovoltaic installations on reservoirs and lakes.
Factory rooftop, warehouse, carport and BESS DC-side wiring for commercial and industrial PV projects.
Representative cable supply records across PV, building wire, drag chain and data cabling. Browse the full project portfolio or request detailed references under NDA.
PV1-F Solar Cable / Solar BoS Supply
PV cable supply to an Iraqi distributor running a retail solar outlet — sold alongside photovoltaic panels and distribution boards in the store’s inventory. Repeating order cycle with print marking and cut lengths tuned for shop-floor retail.
SCOPE // PV Cable | REGION // Middle East
BVR / RVV / RVVP
BVR single-core flexible wire, RVV and screened RVVP supplied to GIIC (Thailand) for in-house consumption on the company’s automotive wiring assemblies. Direct factory supply with repeat procurement.
SCOPE // BVR + RVV + RVVP | REGION // Southeast Asia
PV1-F / Power Cable / Network Cable
Integrated cable supply for a Congolese infrastructure project — PV1-F solar cable for the DC side, low-voltage power cable for the AC distribution, and network cable for site communications.
SCOPE // PV + Power + Network | REGION // Africa
ANPU Cable Group is a China-headquartered manufacturer founded in 1998. Every production batch — PV1-F included — passes full electrical, insulation and flame-retardancy testing before release.
Years of cable manufacturing
In-house testing laboratory
QC testing devices
Engineers & QC staff
CCC, CE (EU export), ISO 9001:2015, ISO 14001, ISO 45001, and Hubei Provincial Industrial Production License.
Product-specific test reports available on request — visit the Service Center for the relevant test reports.
VIDEO // Production line walkthrough
The questions ANPU receives most often from EPC contractors, distributors and project developers.
PV1-F is the designation under IEC 62930 (international standard). H1Z2Z2-K is the designation under TÜV 2 PfG 1169 (European origin). Both describe single-core photovoltaic cables with cross-linked insulation for DC applications. The technical requirements are substantially equivalent — the main difference is the certifying body and standard reference. ANPU manufactures the cable to IEC 62930 as the standard; the H1Z2Z2-K variant is produced as a built-to-specification customized order.
Yes. Because national and international standards differ in conductor class, insulation thickness, sheath material and test sequence, ANPU produces equivalent variants as built-to-specification custom orders rather than dual-marking a single SKU. Specify your target standard at RFQ stage — the engineering team will confirm the build, run samples and manufacture to match.
No. IEC 131 type supports free movable, hanging and fixed laying. IEC 132 is limited to fixed installation only. Neither is rated for direct burial. For underground DC runs, install the cable inside protective conduit or cable troughs, or specify a cable with explicit direct-burial rating.
MOQ is flexible and depends on cable size and customization level. ANPU supports trial orders for verification before mass production. Common sizes (4 mm², 6 mm², 10 mm²) in black are typically held in stock for faster dispatch. Contact the sales team for project-specific quantities.
Technical datasheets, routine test records and factory management certifications (CCC, CE, ISO 9001/14001/45001) are available on request. IEC 62930 type test reports and IEC 60332-1-2 flame test records can be provided per SKU. For project-specific third-party testing, the in-house 3,000 m² laboratory can arrange tailored testing programs.
Yes. PV1-F in standard sizes (2.5 / 4 / 6 / 10 mm²) is compatible with MC4 and MC4-equivalent connectors from all major manufacturers. The cable outer diameter is designed to fit standard MC4 gland sizes. Pre-assembled cable harnesses with MC4 connectors crimped and tested are also available on request.
Typical lead time is 7–15 working days depending on cable type, structure complexity and order quantity. For stocked sizes, dispatch can be faster. Urgent orders are evaluated case by case — message the team on WhatsApp to confirm availability for your timeline.
Share your target standard (PV1-F, H1Z2Z2-K, or regional designation), cross-section, length and any OEM marking requirements. ANPU’s sales team replies within 24 hours.
Engineered Resilience, Delivered Precision
Let us connect you with one of our cable experts to discuss your project.
Getting started is easy: fill out the form on this page to be connected with sales. We’ll take care of the rest.
Can’t wait? Feel free to give us a call at +8615927641447 or +8615827385605