01 // Overview
Multi-Core Control Circuits
KVV is the base member of a multi-core PVC insulated, PVC sheathed control cable manufactured to IEC 60227 / GB/T 9330-2008. The construction is built around a rigid Class 2 stranded copper conductor rated at 450/750 V as standard — engineered for fixed indoor control wiring across switchrooms, MCCs, building management systems and lift/HVAC plant rooms. Up to 61 cores in a single cable, with colour-coded PVC insulated cores under a PVC outer sheath.
Day to day, the cable handles panel internal wiring, MCC auxiliary circuits, BMS sensor and actuator runs, plus switchroom protection / metering links. When a project requires a flexible 0.6/1 kV or international equivalent, the same production line can adapt the conductor class, voltage grade and drum marking so the delivered cable matches the drawings on arrival.
02 // Specifications
Technical Datasheet
Type-test values for the standard build. Flexible, screened, armoured and international-equivalent constructions differ ? ask us for the variant datasheet.
Cable Designation
KVV (IEC 60227 / GB/T 9330-2008)
Rated Voltage
450/750 V · 0.6/1 kV optional
Conductor
Class 2 stranded — rigid copper
Conductor Standard
IEC 60228:2004 Class 2
Insulation
PVC · colour-coded ≤10 cores
Cores
2 – 61
Conductor Sizes
0.75 – 10 mm²
Operating Temp
−20 °C to +70 °C
Voltage Test
3 kV / 5 min — core to core
Flame Retardant
IEC 60332-1-2
Min Bending Radius
10 × Outer Diameter (fixed)
Outer Sheath
PVC · black standard
Flexible Variant
KVVR (Class 5 fine-stranded)
Shielded Variant
KVVP · KVVRP (Cu braid ≥85%)
Armoured Variant
KVV22 (double steel tape)
International Equiv.
YY (YSLY) · NYY-J — customised
All values measured at 20 °C ambient. Custom builds deviate where flagged on the variant datasheet.
Conductor Resistance & Voltage Drop
Class 2 stranded copper conductor — DC resistance per IEC 60228:2004 at 20 °C. Use these values for control-circuit sizing and voltage-drop calculation.
| Nominal Section (mm²) | Strand Construction | DC Resistance @ 20 °C (Ω/km) | Current Capacity 30 °C (A) | Insulation Thickness (mm) |
|---|---|---|---|---|
| 0.75 | 24 × 0.20 | ≤ 26.0 | 12 | 0.6 |
| 1.0 | 32 × 0.20 | ≤ 19.5 | 15 | 0.6 |
| 1.5 | 30 × 0.25 | ≤ 13.3 | 18 | 0.7 |
| 2.5 | 50 × 0.25 | ≤ 7.98 | 26 | 0.8 |
| 4.0 | 56 × 0.30 | ≤ 4.95 | 34 | 0.8 |
| 6.0 | 84 × 0.30 | ≤ 3.30 | 44 | 0.8 |
| 10.0 | 84 × 0.40 | ≤ 1.91 | 61 | 1.0 |
Flame retardance per IEC 60332-1-2 — single vertical wire flame test. Higher-class flame performance (IEC 60332-3-24 category C bundled) available on the LSZH derivative.
Cable Dimensions & Weight
| Model Specification | Overall Outer Ø (mm) | Approx. Weight (kg/km) |
|---|---|---|
| KVV 450/750 V 4×0.75 | 9.2 | 98 |
| KVV 450/750 V 7×0.75 | 11.5 | 153 |
| KVV 450/750 V 4×1.0 | 9.8 | 120 |
| KVV 450/750 V 7×1.0 | 12.2 | 188 |
| KVV 450/750 V 4×1.5 | 11.0 | 158 |
| KVV 450/750 V 7×1.5 | 13.8 | 248 |
| KVV 450/750 V 10×1.5 | 16.0 | 338 |
| KVV 450/750 V 19×1.5 | 22.0 | 610 |
| KVV 450/750 V 37×1.5 | 31.0 | 1,120 |
| KVV 450/750 V 4×2.5 | 13.0 | 238 |
| KVV 450/750 V 7×2.5 | 16.5 | 380 |
| KVV 450/750 V 4×4 | 15.5 | 358 |
| KVV 450/750 V 4×6 | 18.5 | 520 |
| KVV 450/750 V 4×10 | 24.5 | 900 |
03 // Built-to-Spec
Standard control cable + made-to-spec range
ANPU manufactures the standard multi-core PVC control cable to IEC 60227 / GB/T 9330-2008. Beyond the catalogue construction, the same platform is tailored to the project’s flexibility, EMC, mechanical-protection and international-standard requirements.
Specify the variant. ANPU manufactures to match.
Send us the required cable type, cores ? cross-section, voltage rating and sheath colour. Engineering confirms the spec, runs a trial in our 3,000 m? lab, then we put it on the line for your project.
KVV
IEC 60227 · GB/T 9330-2008 — Rigid Multi-Core Control
ANPU’s standard production type. Common sizes (4×1.5, 7×1.5, 10×1.5, 4×2.5, 7×2.5 mm²) typically held in stock for fast worldwide dispatch.
- Class 2 rigid copper · 450/750 V standard
- 2 – 61 cores · 0.75 – 10 mm²
- IEC 60332-1-2 flame retardant
- 0.6/1 kV dual-rating on customised orders
KVVR · KVVP · KVVRP
Flexible Conductor · Copper-Braid Shielded
Flexible and screened derivatives of the base construction. Choose fine-stranded conductors for movement, copper-braid screening for EMI routes, or combine both for movable equipment in noisy environments.
- Flexible conductor option for panel wiring and movable equipment
- Screened option with tinned-copper braid for VFD-adjacent routes
- Flexible screened construction for robotics and dynamic runs
- Same 2?61 core, 0.75?10 mm? sizing range
KVV22 · YY (YSLY) · NYY-J
Steel-Tape Armoured · International 0.6/1 kV Equivalents
Mechanical protection for direct-burial routes, plus the international equivalents we customise for European, Middle Eastern and EPC project drawings.
- Armoured construction for buried or crush-risk routes
- International flexible PVC control-cable equivalents for VDE / EN projects
- 0.6/1 kV control-cable equivalent available where specified
- Chinese and international designations can be printed on one drum label
How a Custom Order Runs
STEP 01
RFQ + Target Spec
Send the required designation, cores ? size, voltage rating, sheath colour, length and any marking requirement. Sales replies within 24 hours.
STEP 02
Engineering Review
R&D engineers confirm the build spec — verify the conductor class, screen coverage, armour layup, voltage rating and standard cross-references — and issue a technical proposal for your sign-off.
STEP 03
Sample + Test Report
Trial production with full electrical (DC resistance, HV withstand 3 kV / 5 min, insulation resistance) and dimensional inspection in the 3,000 m² in-house laboratory. Samples shipped on request.
STEP 04
Bulk Manufacturing
Mass production with 100% routine factory testing per IEC 60227. Packaging on plastic spools or non-returnable wooden drums per the shipping preference. SGS / BV / TÜV / Intertek pre-shipment inspection on request.
04 // Applications
Where This Control Cable Is Deployed
From control-panel internal wiring to switchroom protection-relay links, this cable platform handles fixed 450/750 V control wiring.
Control Panel & MCC Wiring
Multi-core links between terminal blocks, relay modules and I/O sub-panels in switchrooms, substations and MCC compartments. Use a screened construction where routes pass near VFDs or motor starters.
Building Management Systems
Sensor and actuator signal wiring for HVAC, lighting, access and fire-safety control in commercial buildings, data centres, hotels and hospitals — in BMS-dedicated trunking segregated from power.
Switchroom & Substation Control
Protection-relay, metering and control-cubicle multi-cores within electrical switchrooms — segregated from HV busbars by physical distance and metallic barriers.
Lift, HVAC & Plant-Room Control
Controller-to-motor, interlock and safety-circuit wiring for lift machine rooms, AHU controllers, chiller plant panels and pump starters. Use an armoured construction for buried or crush-risk routes.
05 // Project Cases
Control Cable Project References
Representative production and delivery records. Browse the full project portfolio or request detailed references under NDA.
7?1.5 mm? ? Multi-Core Control
UK Distribution Partner ? 7?1.5 mm?
A scheduled consignment produced for a long-term UK channel partner, supplying their downstream control-panel builders, building-services contractors and electrical wholesalers.
MARKET // UK | STATUS // Shipment-ready
Flexible ? Screened ? Armoured
Mixed Derivative Production
A mixed derivative run across flexible, screened, flexible-screened and armoured constructions, produced consecutively on a single matched line for a project bill of materials.
SCOPE // Multi-SKU | STATUS // In production
Projects
Browse the Full Project Portfolio
From the standard build to fully made-to-spec derivative and international-equivalent orders ? ANPU delivers multi-SKU project supply across building wire, control, communication and PV cable.
LINK // apscable.com/projects | NDA // On request
06 // The Manufacturer
28+ Years. 3,000 sqm Lab. 100% Routine Testing On Every Drum.
Years of cable manufacturing
In-house testing laboratory
QC testing devices
Engineers & QC staff
Factory-Level Quality Management
CCC, CE (EU export), ISO 9001:2015, ISO 14001, ISO 45001, and Hubei Provincial Industrial Production License. Product-specific test reports available on request — visit the R&D & testing capabilities page for the full equipment list, or contact sales for SGS / BV / TÜV / Intertek pre-shipment inspection.
07 // FAQ
Engineer & Procurement FAQ
The questions ANPU receives most often from panel builders, EPC contractors and distributors before placing a control-cable order.
Is KVV the same as YY cable?
Functionally similar, but not identical in construction. KVV is the Chinese GB / IEC standard for an unscreened multi-core control cable with a rigid Class 2 stranded copper conductor rated at 450/750 V. YY (YSLY) is the international VDE / EN equivalent, built with a flexible Class 5 fine-stranded conductor at 0.6/1 kV, with a grey sheath. ANPU produces both — KVV as standard and YY / YSLY as a customised order on the same line.
Is KVV a flexible cable?
No. The standard construction uses a Class 2 stranded rigid conductor for fixed indoor installation ? cable tray, conduit and wall runs that do not move. For panel internal wiring, drag-chain runs and other movable applications, specify a flexible derivative or an international flexible construction.
How do the main constructions differ?
Start with the rigid unscreened base construction, then choose the required feature: fine-stranded conductors for flexibility, copper-braid screening for EMI protection, both features together for movable screened routes, or steel-tape armour for buried and crush-risk installations.
What is the rated voltage of KVV?
450/750 V is the standard catalogue rating per IEC 60227 / GB/T 9330 in the great majority of sizes. For projects specifying 0.6/1 kV — typical of European EPC and Middle Eastern drawings — ANPU supplies a customised dual-rated version, with both voltage classes marked on the drum and test certificate. State the required rating with your enquiry.
Can KVV be directly buried underground?
Standard unarmoured PVC control cable should not be directly buried because it has no crush protection against soil, stones or excavation. Pull it through a pre-installed duct, or use the armoured construction designed for direct burial.
What is the MOQ and lead time?
MOQ is flexible and depends on cross-section, core count and customisation level ? trial orders supported. Typical lead time is 7?15 working days for the standard construction and 10?20 working days for customised derivative or international-equivalent builds. Contact sales to confirm availability for your timeline.
08 // Get a Quote
Specify the Variant. ANPU Builds to Match.
Share the required cable type, cores ? cross-section, voltage rating, sheath colour and any OEM marking. ANPU’s sales team replies within 24 hours with quotation, datasheet and lead time.