Cat 6A Shielded Network Cable

FTP CAT6A 4PRS for 500 MHz shielded structured cabling

01 // Overview

FTP CAT6A 4PRS for 500 MHz shielded structured cabling

ANPU Cat 6A shielded network cable is an FTP CAT6A 4-pair Ethernet cable for commercial structured cabling where 500 MHz transmission and foil shielding are required. It is used between working-area outlets and distribution frames in data center, security monitoring, office and home network cabling systems.
02 // Specifications

Technical Datasheet

Executive standard
IEC 61156-5:2020
Product structure
FTP CAT6A 4PRS
Conductor
Stranded conductor, 0.57 mm
Insulation
PE/FEP, 0.25 mm
Twist pitch
<= 20 mm
Shielding
AL-Mylar, 0.05 mm
Shielded connecting wire
1/0.35
Sheath
PVC/LSZH, 0.6 mm
Operating temperature
+20 deg C to +60 deg C
Maximum transmission frequency
500 MHz
Finished cable outer diameter
7.6 mm
Cable weight
17.1 kg/305 m
Flame retardant characteristic
Complies with IEC 60332-1-2

Electrical Performance

DC resistance of single conductor at 20 deg C<= 9.5 ohm/100m
DC resistance unbalance between two internal conductors<= 2%
Dielectric strength between conductors1kV/1min DC
Insulation resistance at 20 deg C>= 5000 Mohm-km
Working capacitance<= 5.6 pF/100m
Line-to-ground capacitance unbalance<= 160 pF/100m

Mechanical Property

Original tensile strength of insulation>= 16 MPa
Original breaking elongation of insulation>= 200%
Original tensile strength of sheath>= 10 MPa
Original breaking elongation of sheath>= 125%
03 // Built-to-Spec

Cat 6A Shielded Network Cable Customization Options

Cat 6A Shielded Network Cable can be customized around construction, voltage class, conductor, insulation, sheath, marking, packing and documentation requirements.

ANPU supports project-based cable supply for engineering drawings, procurement specifications and export shipment plans.

Specify Your Required Construction. ANPU Manufactures to Match.

Share the construction, standard, marking, packing and documentation requirements. ANPU’s engineering team confirms the build before production.
CUSTOM // OEM // ODM
CUSTOM OPTION
VARIANT 01

Cable Construction

Cat 6A Shielded Network Cable can be supplied as FTP CAT6A 4PRS for matching installation environment, electrical performance and project documentation needs.
CUSTOM OPTION
VARIANT 02

Project Specification

ANPU can quote by rated voltage, conductor (Stranded conductor, 0.57 mm), insulation, sheath (PVC/LSZH, 0.6 mm), marking and packing requirements.
CUSTOM OPTION
VARIANT 03

Standards & Marking

Manufacturing, cable marking and datasheet details can be prepared with reference to IEC 61156-5:2020.
CUSTOM OPTION
VARIANT 04

Custom Supply

Jacket color, print legend, cable length, reel or coil packing and export documents can be arranged for project orders.

Available Build Options

OPTION 01
FTP CAT6A standard production
FTP CAT6A standard production keeps the product structure aligned with FTP CAT6A 4PRS. Conductor: Stranded conductor, 0.57 mm.
OPTION 02
PVC or LSZH sheath on request
PVC or LSZH sheath on request lets buyers select the outer material or jacket finish for installation and compliance needs. Sheath/Jacket: PVC/LSZH, 0.6 mm.
OPTION 03
Custom color and reel packing
Custom color and reel packing supports cable identification, circuit grouping and brand or project marking on the outer jacket.
04 // Applications

Where Cat 6A Shielded Network Cable Is Used

Cat 6A Shielded Network Cable is designed for structured cabling projects that require the specified Cat-family construction, transmission frequency and jacket option. It supports commercial network routes where stable pair geometry and installation consistency matter.
01

500 MHz structured cabling

Cat 6A Shielded Network Cable is used in structured cabling projects that need controlled pair geometry, consistent jacket quality and organized LAN cable installation.
02

Commercial office networks

Cat 6A Shielded Network Cable supports office network cabling, workstation links and equipment-room runs where clean routing and 500 MHz Ethernet cable performance are required.
03

Data-center cabling

Cat 6A Shielded Network Cable can be used for data-center cabinet cabling, network patch cable areas and horizontal distribution routes where cable diameter, packing length and route management matter.
04

Shielded security monitoring systems

Cat 6A Shielded Network Cable is suitable for camera, access-control and monitoring network routes that need stable signal transmission and reliable jacket protection.
05 // Project Cases

Project References

ANPU supports project cable supply for building, industrial, power, control and communication applications, with construction, packing and documentation aligned before shipment.

PROJECT 01
Cat 6A Shielded Network Cable

Cat 6A Shielded Network Cable Supply Scope

ANPU can supply FTP CAT6A 4PRS with matched conductor, insulation, sheath, marking and packing requirements for purchase orders.
SCOPE // Project reference | STATUS // Available on request
PROJECT 02
Cat 6A Shielded Network Cable

500 MHz structured cabling Project Use

For 500 MHz structured cabling and Commercial office networks, Cat 6A Shielded Network Cable can be prepared around route length, installation environment and documentation needs.
SCOPE // Project reference | STATUS // Available on request
PROJECT 03
Cat 6A Shielded Network Cable

Cat 6A Shielded Network Cable Inspection & Delivery

Before shipment, ANPU can check Stranded conductor, 0.57 mm, PVC/LSZH, 0.6 mm and IEC 61156-5:2020, then provide packing labels and export documents.
SCOPE // Project reference | STATUS // Available on request
06 // The Manufacturer

ANPU Cable Manufacturing & Quality Control for Cat 6A Shielded Network Cable

For network cable and Ethernet cable orders, ANPU controls conductor size, insulation diameter, pair twist, shield structure when specified, jacket thickness and transmission-related inspection items. Cat 6A Shielded Network Cable orders are prepared around IEC 61156-5:2020, Stranded conductor, 0.57 mm and PVC/LSZH, 0.6 mm. Project orders can include agreed marking, datasheet, packing label and shipment documentation.

28+ Years
300+ Staff
70+ Countries
Pair & Jacket QC
Factory-Level Quality Management
CE certification mark — ANPU Cable products certified for European Union market export
CCC China Compulsory Certification mark
UL-Certified — ANPU Cable Group
RoHS compliant certification mark
FQC Standard Certificate of Compliance
CE (EU export), CCC (China Compulsory Certification), UL, RoHS Compliant and Final Quality Control (FQC) sign-off on every drum. ISO 9001:2015, ISO 14001 and ISO 45001 management systems, plus Hubei Provincial Industrial Production Licence — product-specific test reports available on request via the Service Center.
07 // FAQ

Engineer & Procurement FAQ

What transmission frequency does Cat 6A Shielded Network Cable support?

+
This network-cable construction supports 500 MHz.

What conductor is used in Cat 6A Shielded Network Cable?

+
The conductor construction is Stranded conductor, 0.57 mm.

What sheath or jacket does Cat 6A Shielded Network Cable use?

+
The sheath/jacket construction is PVC/LSZH, 0.6 mm.

What is the finished cable diameter?

+
The finished cable outer diameter is 7.6 mm.

What temperature range applies to Cat 6A Shielded Network Cable?

+
The temperature reference is +20 deg C to +60 deg C.

What flame performance is available?

+
The flame performance reference is Complies with IEC 60332-1-2.

What standard is referenced for Cat 6A Shielded Network Cable?

+
Cat 6A Shielded Network Cable is manufactured with reference to IEC 61156-5:2020.

What does FTP CAT6A 4PRS mean?

+
FTP CAT6A 4PRS refers to the category level, pair count and shielding/UTP construction used for this network cable.

Where is Cat 6A Shielded Network Cable commonly used?

+
Typical applications include 500 MHz structured cabling, Commercial office networks, Data-center cabling.

How is this different from Cat6 network cable?

+
Cat6A is specified for 500 MHz transmission, while the Cat6 UTP construction is specified for 250 MHz.
08 // Get a Quote

Send ANPU Your Cat 6A Shielded Network Cable Requirements

Share the required specification, construction, quantity, marking, packing and documentation. ANPU will confirm the details before quotation.

Related Products

Engineered Resilience, Delivered Precision

Request A Quote

Let us connect you with one of our cable experts to discuss your project.

Getting started is easy: fill out the form on this page to be connected with sales. We’ll take care of the rest.

Can’t wait? Feel free to give us a call at +8615927641447 or +8615827385605

Request A Quote