H07V-K Cable

Single-core PVC insulated flexible copper building wire

01 // Overview

Flexible Wire for Panel & Cabinet Circuits

H07V-K is a 450/750V PVC insulated flexible single-core wire for the internal wiring of control cabinets, switchgear and distribution panels. Its Class 5 fine-stranded copper conductor is easy to bend and route through confined spaces, while the unsheathed single-core construction keeps panel wiring compact. The standard range covers 0.5-95 mm².

ANPU manufactures H07V-K to EN 50525-2-31. The same basic construction appears as 60227 IEC 02 under IEC 60227-3 and as RV on Chinese specifications. When a project calls for a UK or regional equivalent, the same production line builds it to that designation’s own voltage, temperature and marking requirements — see the customization section below.

02 // Specifications

Technical Datasheet

The H07V-K cable specification below follows ANPU’s standard product data. This H07V-K datasheet is intended for procurement and engineering review; marking and the referenced standard are confirmed for each order.

Rated voltage
450/750V
Standard
IEC 60227-3 / EN 50525-2-31 / GB/T 5023.4
BVR standard reference
IEC 60227-3:1997 / JB/T 8734.2-2016
Conductor
Class 5 fine-stranded flexible copper per IEC 60228 for H07V-K positioning
Insulation
PVC/C insulation
Sheath
No outer sheath
Core configuration
Single core only
Sizes available
0.5-95 mm²
CN code
BVR
Maximum conductor temperature
70°C continuous; 160°C short-circuit
03 // Built-to-Spec

Standard H07V-K + Made-to-Order Regional Range

ANPU manufactures H07V-K to EN 50525-2-31 as the standard product line. Beyond standard production, the same single-core platform is built to order for the IEC, Chinese, UK or regional specification named on the project drawing, with the voltage class, insulation, temperature rating and marking adjusted where required.

Specify the designation and target standard. ANPU manufactures to match.

Send the designation, standard reference, conductor size, colour, length and marking. ANPU’s engineering team checks the cross-reference and confirms the construction before production.

CUSTOM // OEM // ODM
● Standard Production
VARIANT 01

H07V-K

EN 50525-2-31 · 450/750V

ANPU’s standard production type for European project schedules, switchgear and control-cabinet wiring.

  • Class 5 flexible copper conductor
  • PVC/C insulation, no outer sheath
  • 0.5-95 mm² available range
  • IEC colours and project marking
⚙ Built-to-Spec
VARIANT 02

60227 IEC 02 · RV

IEC 60227-3 · GB/T 5023.4 — corresponding designations

For IEC schedules and Chinese specifications that use their own designation for the same basic 450/750V Class 5 PVC wire. ANPU produces and marks the cable against the standard stated on the order.

  • IEC or Chinese designation on the marking
  • Class 5 conductor to IEC 60228
  • Single-core PVC insulated construction
  • Datasheet issued to the selected standard
⚙ Built-to-Spec
VARIANT 03

2491X · NYAF · THW(f)

Regional panel-wire references — own standards and ratings

Related regional types ANPU also builds to order, each produced to the voltage, temperature class and construction required by its own standard and confirmed against the project drawing.

  • 2491X for UK schedules, from 1.5 mm² upward
  • kabel NYAF / NYAF cable for Indonesian enquiries
  • THW(f) for Thai and VCm-70 for Vietnamese schedules
  • RK for Nordic project references

How Custom Production Works

STEP 01
RFQ + Target Standard

Send the designation, standard reference, size, colour, length and marking shown on the project documents.

STEP 02
Engineering Review

ANPU checks the conductor class, voltage, insulation, temperature rating and standard cross-reference, then confirms the build for approval.

STEP 03
Sample + Test Report

Trial production and product-specific test documents can be arranged when the project requires approval before the bulk order.

STEP 04
Bulk Manufacturing

Mass production follows the approved specification, with batch QC and coil or reel packing to the shipping requirement.

04 // Applications

Where H07V-K Flexible Wire Is Used

H07V-K wire is used where a flexible single conductor simplifies routing and termination inside protected electrical installations.

01

Control Cabinets

Internal cabinet wiring where flexible conductors help with tight routes, colour identification and terminal connections.

02

Distribution Panels

Panel wiring arranged by conductor size and colour for the specified 450/750V circuit.

03

Conduit Wiring

Protected fixed wiring installed in conduits, surface routes or concealed wiring paths.

04

Equipment Connections

Appliance, instrument and equipment wiring that requires a flexible copper conductor with PVC insulation.

05 // Project Cases

Typical H07V-K Supply Scopes

H07V-K orders are prepared around the approved construction, circuit colours, marking and export documentation. The examples below describe supply scopes rather than fixed stock configurations.

STANDARD SUPPLY
H07V-K / 450/750V

Flexible Panel Wire

Supply to the confirmed conductor size, PVC/C insulation, colour and EN or IEC reference stated on the purchase order.

SCOPE // Standard construction   |   STATUS // Quoted to order

PROJECT MARKING
Colour / Legend / Packing

Panel Wiring Sets

Core colours, print legend, production lengths and coil or reel packing can be prepared for the project schedule.

SCOPE // Project identification   |   STATUS // Confirmed before production

EXPORT ORDER
Regional designation review

Local Standard Check

When an enquiry uses 2491X, NYAF, THW(f), VCm-70 or RK, the local standard is checked before a product match is confirmed.

SCOPE // Export specification   |   STATUS // Engineering review

06 // The Manufacturer

28+ Years. 3,000 m² Lab. Full QC on Every Batch.

ANPU Cable Group is a China-headquartered manufacturer founded in 1998. H07V-K production is checked for conductor construction, insulation, electrical performance, colour identification and packing before release.

28+
Years of cable manufacturing
3,000 m²
In-house testing laboratory
300+
QC testing devices
70+
Engineers & QC staff
Factory-Level Quality Management
CE certification mark — ANPU Cable products certified for European Union market export
CCC China Compulsory Certification mark
UL-Certified — ANPU Cable Group
RoHS compliant certification mark
FQC Standard Certificate of Compliance

CCC, CE, ISO 9001:2015, ISO 14001 and ISO 45001 management systems. Product-specific test reports are available on request through the Service Center.

07 // FAQ

Engineer & Procurement FAQ

The questions ANPU receives most often from panel builders, distributors and EPC contractors when a drawing uses another designation for flexible panel wire.

Are H07V-K, 60227 IEC 02 and RV the same cable?

+

They describe the same basic 450/750V single-core Class 5 PVC construction in different designation systems. H07V-K is the European designation under EN 50525-2-31, 60227 IEC 02 is the IEC reference, and RV is used on Chinese specifications. ANPU applies the designation and standard required by the order.

Are H07V K Cable and H07VK different products?

+

No. H07V K Cable and H07VK are common spelling variations of H07V-K. They do not describe a different voltage class or construction.

Is 2491X Cable the same as H07V-K?

+

Comparable, but the name should not be substituted without checking the size and standard. UK specifications use 2491X for a 450/750V flexible single-core PVC wire from 1.5 mm² upward. ANPU confirms the requested construction against the drawing before quotation.

Can ANPU supply NYAF, THW(f), VCm-70 or RK?

+

Yes, as made-to-order regional types. NYAF is used in Indonesian enquiries, THW(f) in Thai schedules, VCm-70 in Vietnam and RK in Nordic specifications. Each is built to its own local voltage, temperature and construction requirements rather than relabelled from a standard H07V-K order.

What is the H07V-K current rating?

+

H07V-K does not have one current value for every size. Current-carrying capacity depends on conductor cross-section and installation conditions, so the circuit load and installation method must be considered during cable sizing.

How do H05V-K, H07V2-K and Tri Rated Cable differ?

+

H05V-K is rated 300/500V. H07V2-K is used where a higher temperature class is required, while Tri Rated Cable follows a separate multi-standard high-temperature specification. ANPU treats all three as separate products, not as alternate markings for H07V-K.

08 // Get a Quote

Tell ANPU the Standard on Your Drawing.

Share the designation, standard reference, conductor size, colour, quantity and marking. Whether the drawing says H07V-K, 60227 IEC 02, RV or a regional type, ANPU will confirm the construction and rating before quotation.

Related Products

Engineered Resilience, Delivered Precision

Request A Quote

Let us connect you with one of our cable experts to discuss your project.

Getting started is easy: fill out the form on this page to be connected with sales. We’ll take care of the rest.

Can’t wait? Feel free to give us a call at +8615927641447 or +8615827385605

Request A Quote